RivGen Controller Performance Raw Data, Igiugig, AK

Publicly accessible License 

Contains raw data for operations of Ocean Renewable Power Company (ORPC) RivGen Power System in Igiugig 2015 in Matlab data file format. Two data files capture the data and timestamps for data, including power in, voltage, rotation rate, and velocity.

Location, Description, Format,
Column 1, Date and time, MM/DD/YYYY, hh:mm:ss,
Column 2, DC voltage (after DC filter), VDC,
Column 3, DC current into inverters, IDC,
Column 4, DC current into secondary resistive load, IDC,
Column 5, Power into inverters, kW,
Column 6, Power into secondary load, kW,
Column 7, Frequency of single phase AC voltage from generator, Hz,
Column 8, rotation rate of generator/turbine (rested at 1.1 when stationary), rad/s,
Column 9, Velocity Algorithm 2, m/s,
Column 10, Velocity Algorithm 3, m/s,
Column 11, Rcodes for secondary load, see document "SL Controller PLC Memory",
Column 12, Voltage measured between phase A and B, Vll,

Citation Formats

Ocean Renewable Power Company. (2015). RivGen Controller Performance Raw Data, Igiugig, AK [data set]. Retrieved from https://dx.doi.org/10.15473/1287280.
Export Citation to RIS
McEntee, Jarlath. RivGen Controller Performance Raw Data, Igiugig, AK. United States: N.p., 18 Dec, 2015. Web. doi: 10.15473/1287280.
McEntee, Jarlath. RivGen Controller Performance Raw Data, Igiugig, AK. United States. https://dx.doi.org/10.15473/1287280
McEntee, Jarlath. 2015. "RivGen Controller Performance Raw Data, Igiugig, AK". United States. https://dx.doi.org/10.15473/1287280. https://mhkdr.openei.org/submissions/66.
@div{oedi_66, title = {RivGen Controller Performance Raw Data, Igiugig, AK}, author = {McEntee, Jarlath.}, abstractNote = {Contains raw data for operations of Ocean Renewable Power Company (ORPC) RivGen Power System in Igiugig 2015 in Matlab data file format. Two data files capture the data and timestamps for data, including power in, voltage, rotation rate, and velocity.

Location, Description, Format,
Column 1, Date and time, MM/DD/YYYY, hh:mm:ss,
Column 2, DC voltage (after DC filter), VDC,
Column 3, DC current into inverters, IDC,
Column 4, DC current into secondary resistive load, IDC,
Column 5, Power into inverters, kW,
Column 6, Power into secondary load, kW,
Column 7, Frequency of single phase AC voltage from generator, Hz,
Column 8, rotation rate of generator/turbine (rested at 1.1 when stationary), rad/s,
Column 9, Velocity Algorithm 2, m/s,
Column 10, Velocity Algorithm 3, m/s,
Column 11, Rcodes for secondary load, see document "SL Controller PLC Memory",
Column 12, Voltage measured between phase A and B, Vll,
}, doi = {10.15473/1287280}, url = {https://mhkdr.openei.org/submissions/66}, journal = {}, number = , volume = , place = {United States}, year = {2015}, month = {12}}
https://dx.doi.org/10.15473/1287280

Details

Data from Dec 18, 2015

Last updated Jul 30, 2020

Submitted Dec 18, 2015

Organization

Ocean Renewable Power Company

Contact

Jarlath McEntee

207.610.4318

Authors

Jarlath McEntee

Ocean Renewable Power Company

DOE Project Details

Project Name Advanced Energy Harvesting Control Schemes For Marine Renewable Energy Devices

Project Lead Alison LaBonte

Project Number EE0006397

Share

Submission Downloads